The safety of the decoration of the living room is often neglected by people. In fact, there are not many accidents caused by the wrong way of decoration. Generally speaking, the following points should be noted in the renovation project:
First, do not completely cover the marble floor of the building. Marble is ten times more expensive than floor tiles and wood floors. If the floor is covered with marble, it can make the floor overwhelmed. Especially for the second floor or above, the weight of the floor decoration materials shall not exceed 40 kg/m2 because the house decoration is not certified by the house safety appraisal station.
2. Do not arbitrarily pierce the wall of the load-bearing wall, remove the wall connecting the balcony and the doors and windows, and expand the size of the original door and window or build another door and window. This practice will cause partial cracks in the building and seriously affect the seismic capacity, thus shortening the service life of the building.
Third, the decoration of the balcony and bathroom should try to use materials with small load, because the balcony will be overturned due to excessive overload.
Fourth, the waterproof between the toilets is also a key link in the decoration. The general practice is to block the floor drain and put more than 5 cm of water before the decoration of the toilet room to carry out the water test. If it leaks, it must be re-waterproof; if it does not leak, carefully lay the ground during construction. Do not damage the waterproof layer and tamper with the water and heating system.
5. Use copper wire when selecting wires, and avoid using aluminum wire. Due to the poor electrical conductivity of the aluminum wire, the wire in use is prone to heat, loose joints and even fire. In addition, it should be noted that the construction of the wire can not be directly buried in the wall, should be installed with a regular casing to avoid leakage and fire.
6. During construction, care should be taken to avoid holes, holes, ceilings and art lighting fixtures on the concrete circular hole plate.
7. Indoor decoration should ensure the safety requirements of gas pipelines and equipment. Do not dismantle the pipeline without authorization, so as not to affect the normal operation of the system. In addition, it should be noted that the horizontal clearance between the power pipeline and the equipment and the gas pipeline should not be less than 10 cm, and the cross distance between the electric wire and the gas pipe should be no less than 3 cm.
8. Do not place the gas stove on the wooden floor cabinet during the kitchen decoration, or even pack the gas main valve in the wooden floor cabinet. Once the cabinet is on fire, the gas main valve is difficult to close in the fire, and the consequences will be unimaginable.