Usage and operation of metal seal ball valve

Ball valve classification 1), commonly used ball valve according to their working principle is divided into floating ball valve, fixed ball valve, lifting rod valve and so on. 2), the ball valve according to the channel position can be divided into straight-through, three-way and right angle. The latter two ball valves are used to distribute the medium and change the flow of the medium. Ball valve construction, installation points 1), installation location, height, direction of import and export must meet the design requirements, the connection should be firm and tight. 2), installed in the insulation pipe on all types of manual valves, the handle shall not be down. 3), the appearance of the valve must be installed before the inspection, the valve nameplate should be consistent with the current national standard "General Valve Flags" GB 12220 requirements. For the working pressure is greater than 1.0 MPa and the main pipe to play the role of cut-off valve, the installation should be carried out before the intensity and tightness test, qualified after the standard use. Strength test, the test pressure of 1.5 times the nominal pressure, the duration of not less than 5min, valve housing, packing should be no leakage as qualified. Tightness test, the test pressure is 1.1 times the nominal pressure; test pressure in the test duration should be consistent with GB 50243 standard requirements, no leakage valve plate sealing as qualified. 4), valve flange and pipe flange according to the pipeline design requirements installed gaskets. 5), with the ball valve drive, according to the instructions of the product installation instructions. The use of the ball valve 1, before installing the valve to be sure to confirm the pipeline inside and body channel has been cleaned. 2, the operation of the ball valve driven by the actuator driven valve stem rotation complete opening and closing, forward rotation 1/4 turn (90 °), the ball valve is closed. The ball valve opens when rotated 1/4 turn (90 °) in the reverse direction. 3, when the implementing agency direction arrow parallel with the pipeline, the valve is open; the arrow and the pipeline perpendicular to the direction, the valve is closed. Ball valve to reduce the amount of maintenance methods: To make the hard seal ball valve has a longer service life and maintenance-free period, the valve must be in normal working conditions to maintain a harmonious temperature / pressure ratio, and in line with the valve body material corrosion data. Ball valve maintenance matters needing attention: the ball valve is closed, the pressure inside the valve body still exists pressure fluid. Before servicing the valve, internal pressure must be relieved and the valve must be open to disconnect the power or air supply and to disengage the actuator from the bracket. Then we can split the work in order to repair. Disassembly and reassembly must be careful to prevent damage to the sealing surface of parts, especially non-metallic parts, remove the O-ring should use a special tool to reassemble the valve flange bolts must be symmetrical, step by step, evenly tighten the cleaning agent should be ball valve In the rubber parts, plastic parts, metal parts and working medium (such as gas) are compatible. Non-metallic parts Clean with pure water or alcohol Working medium for gas, gasoline (GB484-89) can be used to clean metal parts. Disassembled individual parts can be cleaned by dipping. Non-metallic parts that remain undistracted may be cleaned with a clean, fine, silk-dipped cleaning cloth (to prevent the fibers from sticking to the parts). Clean all non-metallic parts such as grease, dirt, glue, dust and other non-metal parts adhered to the wall after cleaning, remove it from the cleaning agent immediately, do not immerse it for a long time after cleaning, and then need to be washed. After the surface cleaning agent is volatilized Unwash detergent silk cloth) assembly, but should not be shelved for a long time, otherwise it will rust, dust pollution New parts also need to be cleaned prior to assembly Use grease lubrication. Grease should be ball valve metal materials, rubber parts, plastic parts and working medium are compatible. When the working medium is gas, for example, special 221 grease. Apply a thin layer of grease on the surface of the seal mounting groove and a thin layer of grease on the rubber seal. Apply a thin layer of grease to the sealing surface and the friction surface of the valve stem. Debris, fibers, grease (other than those specified) dust and other impurities, foreign matter and other pollution, adhesion or stay on the surface of the parts or into the lumen. If there is a small amount of leakage occurred at the packing, should be locked stem nut. Note: Do not lock too tight, usually locked 1/4 turn ~ 1 circle, the leak will stop. Hard seal ball valve is suitable for low pressure, small diameter pipe to cut off the water flow and to change the distribution of water or need to quickly open and close the place. 3) small size, light weight; 4), the ball valve sealing surface material selection of plastic, good sealing; 5), easy to operate, open and close quickly, 7), fully open or fully closed, the sealing surface of the ball and the valve seat and the media isolation, the media will not be caused by the passage of time Valve sealing surface erosion.

Medical Accessories

CNC medical accessories refer to precision components used in medical devices that have been produced using computer numerical control (CNC) machines. These accessories are precise and accurate, making them an essential part of medical devices that require high-quality equipment.


CNC medical accessories offer several advantages over traditional manufacturing methods. Due to the precision of the CNC machines, they can create complex parts to exact specifications with minimal errors. This ensures that each component is precisely crafted, leading to high-quality medical accessories that offer superior performance and safety.


CNC medical accessories are used in a range of medical devices, including surgical instruments, implants, and diagnostic equipment. They are produced using a range of materials, including stainless steel, titanium, and plastic.


One of the significant advantages of CNC medical accessories is their versatility. The CNC machines used to produce these accessories can create parts in a wide range of shapes and sizes, making them suitable for a variety of medical applications. Additionally, they can produce parts with intricate shapes and features that would be challenging, if not impossible, to create using traditional manufacturing methods.


CNC medical accessories are also durable and can withstand rigorous medical environments, including sterilization procedures. This ensures that these accessories provide consistent and reliable performance throughout their lifetimes.


Finally, CNC medical accessories are also beneficial in the development of new medical technologies. With their ability to produce complex and precise parts, these accessories offer researchers and manufacturers the ability to create innovative medical devices that provide superior performance and patient outcomes.


In summary, CNC medical accessories are vital components of the modern medical industry. Their precision, accuracy, and versatility make them an essential tool for a wide range of medical applications. With their ability to produce complex and precise parts, they offer the potential for the development of innovative medical technologies that offer high performance and safety for patients.

Hospital Bed Accessories,Oxygen Tank Holder,Oxygen Cylinder Accessories,Stethoscope Watch

Lizhi Precision Manufacturing Technology Co.,Ltd , https://www.lizhipartsmfg.com