Axial flow pump technology tips

Axial flow pump performance adjustment, usually using two methods: 1. Variable speed regulation We already know that axial flow pump is working at a certain speed, and access to the appropriate flow, lift, power and efficiency. When the speed changes, its performance parameters also change accordingly, so as to achieve the purpose of regulation. If the axial flow pump is powered by a diesel engine or a gasoline engine, the throttle speed can be changed by changing the throttle size. If the axial flow pump is connected with the power machine through a V-belt or flat belt indirect transmission device, the diameter of the transmission pulley can be changed to change speed Drive wheel or driven wheel can, the purpose is to change the transmission ratio. Variable speed pump performance, more economical, the scope of application is broader, all agricultural pumps can be used. 2. Variable angle adjustment From the structure point of view, axial pump impeller with a huge hub for easy installation of adjustable angle blades. When the blade installation angle is changed, the blade lift on the water also changed, thus changing the pump performance, which is the axial pump variable angle adjustment. As the blade mounting angle increases and decreases, the axial flow pump flow, lift, power that is changed, however, the highest point of efficiency but no change, it is very conducive to the axial flow pump performance regulation. According to the structure of the impeller, the blade installation angle of the device, the leaves are divided into three types: (1) the fixed blade leaves and wheel cast as a whole, blade installation angle has been fixed in the design and manufacture, can not be adjusted during use . This type of impeller used for small pumps. (2) Semi-adjusting vanes Loosen the fixing nut and set screw of each vane on the impeller hub. Adjust the vane mounting angle according to the requirements and fasten it. General blade mounting angle from the negative 100-180. In this range, according to the requirements to adjust. (3) Leaf-blade leaves with special design of the angle adjustment mechanism to adjust, you do not have to disassemble the impeller, you can directly manipulate the mechanism to change the blade mounting angle, the adjustment range from 0-260. Blade angle adjustment mechanism has two kinds of mechanical adjustment and hydraulic adjustment. This impeller is mostly used for large-scale axial flow pump. Axial pump operation, the pump is not water or water reduce the reason why? How to troubleshoot? Axial pump operation more reliable. However, there are times when problems can occur. Failure, it should be ruled out promptly. Axial pump operation, the pump does not water. Reason for the failure: Remedy: Impeller submerged depth is not enough 1. Lower the pump installation height 2. Pump rotation direction is not 2. Adjust the pump rotation direction 3. Pump speed is too low 3. Change the transmission speed ratio, increase pump speed 4. Impeller and blade Between the rupture or blade fixed 4. reinstall the impeller, tighten the nut, or replace the impeller nut loose, leaves move around 5. leaves a lot of debris around the backwash red mixed several times, still no water, you need Remove the pump to the miscellaneous axial flow pump in operation, reduce the amount of water. Reason for the failure: Remedy: blade outer wear or blade crushing partially 1. Replacement of the impeller lift is too high 2. Adjust the lift, check the water outlet pipe plug phenomenon is not enough depth of the impeller 3. To reduce the impeller installation height The pump speed is less than required 4. Replace the drive pulley to improve the pump speed around the weeds and debris on the leaves 5. Shutdown backwater several red hybrid, plus the trash in the sink mouth To prevent failure, should pay attention to the operation: Attention to changes in the instrument ; Attention to the sound and vibration of the unit pay attention to changes in the water level into the pool, such as into the pool water level down to the minimum level below the prescribed time, should be shut down; pay attention to the cleanliness of the pool, such as the pool of weeds and debris, it should be promptly Picked up Small mobile axial flow pump in what occasions apply? What are the characteristics? In promoting the use of what should pay attention to? Axial flow pumps are generally used for fixed pumping operations, which control irrigation and drainage area is relatively large. In recent years, with the reform of rural production system and the rapid development of aquaculture, a small mobile axial-flow pump has been widely used. Although this pump head is low, but the flow is quite large, and the supporting power is small, stable performance, reliable work, simple structure, small size, light weight, installation and transfer is extremely simple and can be used for small-scale irrigation or drainage ponds, Can also be used for water supply and drainage of other water conservancy projects or construction sites. Small mobile axial flow pump developed by Agricultural Machinery Factory in our province has been formulated as one of series of agricultural water pump with specifications of 4, 6, 8, 10 and 12 inches. Its structural features are as follows: Supporting power are optional vertical motor, coupling direct drive, where in the field erected a place where the grid can be used. Installation form for the mobile vertical, easy to use. In operation, the fault is less. Single-stage impeller, fixed blade, blade number 4. Under the water tube generally installed under the bracket or grating. Pumps, motors, transmissions, and inlet and outlet pipes are all unitary, so the pump is compact. In the promotion of use, should pay attention to the matter: This small pump, flexible, suitable for mobile pumping operations. Generally do not set up pump room, placed in the field pumping, sun and rain, the motor is easy to damp, Moreover, the connection of the motor wire, most of the temporary cable. Therefore, in promoting the use, should pay special attention to electricity safety, so as to avoid electric shock accident. The pump head must be calibrated on the nameplate to use the value, can not arbitrarily increase the outlet pipe, otherwise there may be overloaded. Pump erection, diagonal work can be, when used obliquely, its head to a vertical height meter. Long-term use of the pump, the pump body to be placed upright, and pay attention to motor moisture.

PCR Plates

High-Quality PCR Plates with Universal Compatibility
We have excellent PCR or qPCR performance, and provide a variety of different specifications of PCR Plates to meet your experimental needs. All of our plastic consumables have been verified by engineers to be perfectly compatible with laboratory instruments and have excellent performance.

You can find different types of 96 Well PCR Plates, such as non-skirted, semi-skirted, 0.2ml, 0.1ml, transparent and white PCR plates. There are also 40ul and 50ul 384 Well PCR Plates. We can help you choose the right PCR platform according to your requirements. Please contact us and we will send you samples for free.

More info about PCR Plates:

What Are PCR Plates?

Researchers often use PCR plates in high-throughput screening thermocycler applications due to their compatibility with most thermal cyclers. The uniform and thin walls enable a precise thermal transfer. The wells are often raised slightly to accommodate sealing mat, film, and foil. They are also autoclavable.

Semi Skirted PCR Plate,Non Skirted PCR Plates,Low Profile PCR Plates,Real Time PCR Plate,PCR Reaction Plate

Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yonyuepcrtube.com