Three-phase asynchronous motor maintenance

When starting the winding motor, the starting varistor should be connected to the rotor circuit. For the motor with the brush lifting mechanism, the brush should be lowered, the short circuit device should be disconnected, the stator circuit switch should be closed, and the varistor should be pulled. When the motor is close to the rated speed, lift the brush, close the short-circuit device, and start the motor.

Preparation and inspection before start-up

1. Check whether the grounding of the electric and starting equipment is reliable and complete, and whether the wiring is correct and good.

2. Check if the voltage and frequency indicated on the motor nameplate match the power supply voltage and frequency.

3. Check the relative phase and relative insulation resistance of the winding before starting the motor with new installation or long-term deactivation. The group of insulation should be greater than 0.5 megohms. If it is below this value, the windings must be dried.

4. For the wound rotor, check whether the brush device on the collector ring can work normally and whether the brush pressure meets the requirements.

5. Check if the motor rotation is flexible and whether the oil in the sliding bearing reaches the specified oil level.

6. Check if the rated current of the fuse used in the motor meets the requirements.

7. Check if the fastening bolts and mounting bolts of the motor are tightened.

After all the above checks have met the requirements, the motor can be started. After the motor is started, run at no load for about 30 minutes. Observe whether the motor has abnormal phenomena. If abnormalities such as noise, vibration, and heat are found, take measures. After the situation is eliminated, it can be put into operation.

When starting the winding motor, the starting varistor should be connected to the rotor circuit. For the motor with the brush lifting mechanism, the brush should be lowered, the short circuit device should be disconnected, the stator circuit switch should be closed, and the varistor should be pulled. When the motor is close to the rated speed, lift the brush, close the short-circuit device, and start the motor.

Operational maintenance

1. The motor should be kept clean at all times, and no debris is allowed to enter the motor; the air inlet and outlet should be kept clear.

2. Monitor the power supply voltage, frequency and load current of the motor with the meter. The power supply voltage and frequency must conform to the motor nameplate data. The motor load current must not exceed the specified value on the nameplate. Otherwise, the cause should be identified and measures should be taken.

3. Take necessary measures to detect the temperature rise of each part of the motor.

4. For the wound-wound rotor motor, always pay attention to the contact pressure, wear and spark between the brush and the collector ring. When the motor stops, the switch in the stator circuit should be disconnected, then the brush lift mechanism is pulled to the starting position, and the short circuit device is disconnected.

5. Regular maintenance after the motor is running, generally divided into minor repairs and overhauls. The minor repairs are generally overhauled, and the motor starting equipment and the whole are not disassembled. In the first quarter, the overhaul will remove all the components of the transmission and the motor, and the parts will be thoroughly inspected and cleaned. Usually once a year.

Global hardware network

Concerned about surprises

Label: Three-phase asynchronous motor maintenance

Previous: Analysis of the reasons for step-out motor out-of-step and its solution Next: Precautions for using the cylinder

Stainless Steel Wine Rack/holder

Wine Bottle Rack,Metal Wine Rack,Wine Display Rack,Wine Rack Holder,Honeycomb Wine Rack

Shenzhen Lanejoy Technology Co.,LTD , https://www.compressionspring.net