1. Hydraulics and Other aspects
Due to the unreasonable design of the inlet runner, the influent conditions deteriorate and a vortex is generated. It can cause vibration of the submerged pump. Uneven subsidence of the foundation supporting the Warwick submerged pump and motor can also cause vibration.
2. Hydraulic aspect
The most common cause of vibration of the Warwick submerged pump unit is the cavitation of the submerged pump and the sudden change in pressure in the conveying pipe.
3. Mechanical aspect
The quality of the rotating parts of the submerged pump is unbalanced, rough and shoddy, the installation quality is poor, the axis of the unit is asymmetrical, the pendulum exceeds the allowable value, the mechanical strength and rigidity of the parts are poor, and the bearing and sealing parts are worn and damaged, which will generate strong vibration.
4. Electrical aspect
The motor is the main equipment of the unit. The internal magnetic imbalance of the motor and the misalignment of other electrical systems often cause vibration and noise. Jinan Warwick Pump Co., Ltd.
Concerned about surprises
Label: Analysis of the reason for the large vibration of the submerged pump
Previous: Analysis of the cause of valve leakage Next: Replacement and repair of dust bag
KN95 Mask manufactured by Careable biotechnology Co.,Ltd
- High filtration Efficiency: BFE&BPE≥95%
- In Chinese PPE Export Whitelist
- FDA Registered No:3016678425
- Low Breathing Resistance: Flow Rate≥95 L/Min
- 4 Layers Protection
- ISO9001 Quality Management System Certificate
- Already in stock,ready to ship everytime!
N95 Mask,Mask Ce,4Ply Kn95 Mask,Kn95 Certified 3D Mask
CAREABLE BIOTECHNOLOGY CO,. LTD , https://www.careablemask.com