Red mud biogas bag use and maintenance method

Red mud biogas bag use and maintenance methods, red mud biogas bag products, detailed introduction of red mud biogas bag price and installation, biogas bag collapsible biogas bag, biogas process flow chart, rural biogas equipment purchase, red mud biogas bag, please call Manager of Hongjing Environmental Protection Chen understands the introduction of “Red Mud Gas Bag” 1.1 Fermentation Inoculum Rural biogas fermentation inoculum Generally, a certain amount of human and animal waste is added by the fermentation broth of the old red mud biogas bag. For example, to prepare 500 kg of fermentation inoculum, generally 200 kg of biogas fermentation broth and 300 kg of human and animal feces are mixed, stacked in a water-tight pit and sealed with a plastic film, and used as an inoculum after one week. If there is no biogas fermentation broth, it can be directly packed with 500kg of human and animal waste, and it can be used as biogas fermentation inoculum after 10 days. 1.2 The red mud biogas bag is filled and the sealing performance of the red mud biogas bag is checked to meet the requirements. There are many kinds of biogas fermentation materials, and various organic substances can be used as biogas fermentation materials. Such as: human and livestock poultry manure, crop straw, agricultural and sideline products waste, domestic sewage. The amount of feed should be 60% to 65% of the volume of the red mud biogas bag. After the feed is completed, the water is added to the pool. The amount of water added is 20 cm higher than that of the dry material. Zuihao is a sewage, manure and biogas slurry with higher temperature. It is forbidden to directly extract cold water from the well to avoid red mud gas bag. It is in a "cold immersion" state and is difficult to start. 1.3 Red Mud Gas Bag Starts The second day after the general red mud biogas bag is put into operation, the rise of the barometer can be observed, indicating that gas has been generated in the red mud gas bag. Initially, the gas produced is released (until the barometer drops to zero). Because the gas produced in the early stage of biogas fermentation is mainly carbon dioxide gas, and there is a large amount of air in the pool. The methane gas content is low and usually cannot be burned. When the barometer rises again, it will ignite on the cooker. If it can ignite, it indicates that the red mud biogas bag has started normally. Otherwise, try again as above. 1.4 Red mud biogas bag discharge After the flammable gas generated by the red mud biogas bag is used, the waste must be taken out, and safety must be taken when discharging. Because the red mud biogas bag is fermented in an anaerobic state for a long time, there is no oxygen in the pool, and people are prone to danger after entering. First, open the lid of the pool and ventilate for a certain period of time. Then, ignite the candle and put the candle into the pool with a rope. The candle can continue to burn and the person can enter. If the candle is extinguished, the person cannot enter. 2. Maintenance and fault handling 2.1 The gas pipeline is often inspected for the gas pipeline. The inspection method is: unplug the gas pipeline from the red mud biogas bag air pipe, connect a switch on the gas pipe, and close the lamp and the switch before the stove. One end of the air pipe connecting switch blows or inflates into the gas pipe. When the pressure on the pressure gauge reaches 30 cm water column height, the switch is turned off and the pressure gauge is observed for 3 minutes. When the pressure gauge drops to indicate air leakage, use the above method to raise the pressure to 30 cm water column height, then apply soapy water to the gas pipeline and switch. The place where the air bubbles are generated is the place where the air leaks, and should be repaired and replaced. 2.2 Leakage and air leakage 2.2.1 Carefully observe whether there are cracks or pores on the inner wall of the red mud biogas bag. If the air pipe is loose, use a finger or a small wooden stick to strike the whole area of ​​the pool. Observe the water wall traces. If there is no obvious water seepage, the surface should be cleaned and evenly spread a layer of dry cement powder. If there is a wet or wet line, it will be a leaking hole or a water leaking seam. 2.2.2 Fill the pool with water. After the pool wall absorbs enough water, mark the water level every other day and night. If the water level does not drop, it indicates that the red mud biogas bag does not leak water. If the water level drops to a certain position, it will not drop, indicating that the water is leaking. Mark the water line, carefully look for cracks or pores above the water line, and then drain and repair. 2.2.3 After checking the water leakage by the above method, seal the sealing cover, connect the tee on the gas transmission pipe, connect the pressure gauge to one end, and pump the air to the other end with qiqiang. When the pressure of the pressure gauge reaches 80cm water column, turn off the air switch. After 24 hours, if the water column of the pressure gauge drops 3 to 4 cm, it indicates air leakage. If the water column drops to a certain position, it will not drop, indicating that the pool has no air leakage. When testing the water test pressure, when the water column on the pressure gauge rises to the design position, the pressure is first fast and then slow down to indicate the water leakage, and the uniform speed drop is the air leakage. It was found that water leakage and air leakage were repaired in time. 2.3 The reason for not producing gas is: there is not enough biogas bacteria; the temperature of the liquid in the tank is low; the concentration of the fermentation liquid is too large. Solution: Add appropriate amount of bacteria to increase the temperature inside the pool. Hongjing Environmental Manager Chen WeChat tongbu QQ http://news.chinawj.com.cn Red mud biogas bag use and maintenance method

High Speed Door Motor And Control Box

Our company have German SEW Motor, Japan Mitsubishi Controller. Our own brand Hofic servo motor and controller. Chinese famous brand SEJ motor and Holip controller.

About our German SEW Motor and Japan Mitsubishi Controller: It is easy to find the ideal energy-efficient motor for your application at SEW. The series has a suitable design in its range for the globally applicable efficiency classes. Select the power and frequency within this motor design and you have already taken care of the most important selection criteria.All other motor options are of course available independently of the efficiency class. A comprehensive braking concept and cost-optimised built-in encoders ultimately complement the motor range. Comprehensive braking concept and combinations i.e. up to three different brake sizes per motor size featured in the range: Cost-optimised built-in encoders integrated into the motor. Motors for efficiency classes IE1 to IE4.Compact design saves space and costs. Future-proof, also as regards environmental protection (standards). Reduction in operating costs when using energy-efficient motors; our energy-efficient motors conform to the efficiency classes.

About servo High Speed Door Servo Control System: Our rolling gate servo control system is suitable for high speed and high usage soft and hard rolling gate. The whole system is in a small and light package, it has high torque and high operating speed, lower noise, high reliability, smooth and soft operating curves, it`s suitable for high speed and usage environment. The rolling curtain can be controlled by pull switch, push button, Bluetooth, ground radar, ground magnetic sensors. Operating Speed: 1M/s; Operating Width: <16 ㎡; Daily operating time: >2000 time; Rated voltage: 220v; Rated Output: 0.75 KW/1.5KW.

The system can operated via: 1) control box; 2) inching electronic control; 3) continuous automatic operation; 4) emergency stop; 5) single side operation box; 6) time delay; 7) ground radar and/or magnetic sensors. Please refer to Wiring Terminal for eternal connections.

System has fuse/safety wire shutdown switch for three-phase power protection, fuse/safety wire for operating circuit protection, and temperature sensing relay for motor protection.

Stroke Controller utilizes absolute value encoder. Connect the absolute value encoder and reducer via encoder`s axle, and fix the wings on to the reducer, than insert the aviation plug into plug receptacle.

The mounting screw for the control box must inspect regularly to prevent screw been getting loose and falling off. Check the internal and external wirings. Check and change the oil for the redactor on regular basis.

Precision: The system use Full closed-loop servo control and Double Encoder design. This is to ensure long operating life and to prevent overshooting during operating.

Stability: The system utilizes integrated design concept, in order to simplify internal wiring and prevent any function caused by wiring and terminal connections.

High Speed: Motor max speed is 2500 rpm; door max operating speed is 2 m/s.

Smooth: The torque servo system can adjust torque to the load automatically, and its speed curve mode step less speed regulating to ensure a smooth operation.

About SEJ motor and Holip controller: Three-phase asynchronous motor with magnetic brake has broad uses, It is suitable for various mechanical main drive and auxiliary drive, and it is also used for various required rapid stopping and correct positioning. The braking time within 0.2 second. Electric motor is added the DZM series direct current electromagnetic arrester by the basic series(Y series) electric motor.The protection class of electric motor part is IP44,the arrester part is IP23.if be applicable to bad environment can also make the arrester part into IP44,but customer have to put forward a special request while ordering,the manufactory can design a manufacturing exclusively. Its structure diagram is picture 1 and 2,picture 1 is the structure with hand release.Picture 2 is the structure without the hand release.Its operating principle BE, after being to make the retardation coil(6)to connect direct current power supply,because of the function of electromagnetic force,electromagnet(7)attract gag bit(5),and compress spring(24),make arrester disc(2)away from the friction surface of the gag bit(5)and shield(26)(the electrical motor can immediately operate normally).When the power supply cuts off after,the electromagnet(7)loses electromagnet force,the spring(24)releases the gag bit(5)and compress tightly to arrester disc(2),the arrester function,stop(the motor shaft)quickly,make electric motor shop turning to move,for the second time connect power supply will repeat above-mentioned action.

High Speed Door Motor And Control Box,High Speed Door Motor,High Speed Door Servo Motor,Variable-Frequency Servo Motor

Shenzhen Hongfa Automatic Door Co., Ltd. , https://www.hfgaragedoor.com